  • Logs up to 1000 data points with unique identifiers
  • 16 Independent Detector Setups
  • Microprocessor Based Electronics
  • LCD Display with backlight
  • RS-232 Output
  • Scaler, Ratemeter, Integrated Dose
  • Comes with programmable keypad
  • Bar Code Reader and Download Cable Optional

INDICATED USE:
Field analysis and data logging

COMPATIBLE DETECTORS:
G-M, proportional, scintillation

CONNECTOR:
Series "C" (others available on request )

DISPLAY:
8 line LCD display with 15 characters per line

BACKLIGHT:
A two position toggle switch to turn backlight ON or OFF

SCALER:
6 digit display

TIMER:
Used in conjunction with scaler. Count time can be set from 1 - 65,535 seconds in 1 second intervals

RATEMETER:
Digital ratemeter, corrected for dead time and calibration constant

TREND INDICATOR:
5 decade logarithmic bar graph

LINEARITY:
Reading within plus or minus 10% of true value with detector connected

SCALE:
Can display in rem/hr, Sv/hr, R/hr, cpm, cps, dpm, dps, rad(r), Gray(G), C/kg, Ci/cm squared, or Bq/cm squared

INTEGRATED DOSE:
Counter provided to give total accumulated dose for up to 45 days (Will display in same units as ratemeter )

AUDIO:
Built in unimorph speaker with volume control (greater than 60 dB at 2 feet, full volume )

AUDIO DIVIDE:
Operator selected divisions of 1, 10, or 100 events-per-click

ALARM:
Separate alarms for digital ratemeter, scaler, and integrated dose can be set at any point (audible and visual indicators )

ACK/SCROLL:
Push-button to silence audio after alarm has been indicated and/or scroll through the various displays

DATA LOGGER:
Capable of logging up to 1000 individual data points with unique identifiers for each point

DETECTOR PARAMETERS:
Capable of storing individual parameters for 16 different detectors

RS-232 PORT:
A full duplex communication port that allows for instrument setup by optional keypad or PC. Also allows for data to be transferred to a PC file.

BAR CODE READER (optional):
Allows for setup of instrument by computer generated bar codes

HIGH VOLTAGE:
Adjustable from 200 - 2500 volts

THRESHOLD:
Adjustable from 100 - 1000

WINDOW:
Adjustable from 0 - 1000 above threshold

GAIN:
Adjustable from 2 - 350 mV at threshold setting of 100

DEAD TIME:
Adjustable to compensate for dead time of detector and electronics

RESPONSE:
Fixed: - Adjustable from 1 - 127 seconds in 1 second intervals
Variable: - Will vary according to number of counts present.
Typical times FAST: 4 - 25 seconds, SLOW: 4 - 60 seconds from 10% to 90% of final reading

POWER:
4 each "D" cell batteries (housed in sealed compartment that is accessible from back of instrument)

BATTERY LIFE:
Greater than 75 hours (low battery condition is automatically indicated )

CONSTRUCTION:
Milled and drawn aluminum with beige polyurethane enamel paint

TEMPERATURE RANGE:
32° F(0° C) to 122° F(50° C) (LCD limits temperature range )

SIZE:
6"(15cm)H X 4.3"(11cm)W X 8.8"(22cm)L

WEIGHT:
5 lbs (2.3kg) including batteries